Mass Spectrometry (MS)- Principle, Working, Parts, Steps, Uses
Updated:
Mass spectrometry (MS) is a powerful and versatile technique that can be used to identify and quantify the chemical composition of matter. It can analyze samples ranging from atoms and molecules to complex mixtures and biological macromolecules. Mass spectrometry works by converting the sample into charged particles, called ions, and separating them based on their mass-to-charge ratio (m/z) . The resulting mass spectrum shows the relative abundance of each ion as a function of its m/z value. By comparing the mass spectrum with known reference data, the identity and structure of the sample can be determined. Mass spectrometry has many applications in various fields, such as environmental monitoring, geochemistry, chemical and petrochemical industry, biotechnology, medicine, and forensic science . In this article, we will explain the principle, working, parts, steps, and uses of mass spectrometry in more detail.
The principle of Mass Spectrometry (MS) is based on the deflection of moving ions by electric and magnetic fields. The technique involves the conversion of sample compounds to ions in the gas phase, followed by fragmentation and separation of the ions based on their mass-to-charge ratios . The separated ion beams can be observed or collected using a detector or receiver. The ions present in the mass spectrum provide information about the structure and properties of the compound.
The mass-to-charge ratio (m/z) is a key parameter that determines the deflection of an ion in a mass spectrometer. For most ions, the charge is one, and thus, the m/z ratio is simply the molecular mass of the ion. However, some ions may have multiple charges, which affect their m/z values and deflection angles. The relative abundance of each ion is another parameter that indicates how many ions of a certain m/z value are detected by the instrument.
Mass Spectrometry (MS) can be used to identify the elemental or isotopic signature of a sample, the masses of particles and molecules, and to elucidate the chemical structures of molecules and other chemical compounds. Mass Spectrometry (MS) can also be used to separate isotopes and to measure the abundance of concentrated isotopes when used as tracers in chemistry, biology, and medicine.
Mass spectrometry is a technique that measures the mass-to-charge ratio (m/z) of ions in a sample. It can be used to identify and quantify the compounds in a mixture, as well as their elemental, isotopic, or chemical structure .
The working of mass spectrometry can be summarized by the following steps :
- Ionization: The sample molecules are ionized by knocking one or more electrons off to give positive ions. This can be done by bombarding them with a beam of energetic electrons or by other methods. The ions may have different charges and masses depending on the ionization technique and the sample composition.
- Acceleration: The ions are accelerated by an electric field so that they all have the same kinetic energy. This ensures that the ions with different masses will have different velocities and trajectories in the next step.
- Deflection: The ions are deflected by a magnetic field according to their mass-to-charge ratios. The lighter and more charged ions will be deflected more than the heavier and less charged ones. This separates the ions into different beams based on their m/z values.
- Detection: The ion beams are detected by a device that can measure the intensity and m/z of each ion. This can be done by converting the ions into electrical signals or by recording their impact on a photographic plate. The results are displayed as a mass spectrum, a plot of intensity as a function of m/z.
The mass spectrum can provide information about the identity and abundance of the sample components by comparing the m/z values and intensities of the peaks with known reference data. The mass spectrum can also reveal the structure and fragmentation patterns of the sample molecules by analyzing how they break up into smaller ions under ionization.
Mass spectrometry (MS) is a technique that measures the mass-to-charge ratio of ions produced from a sample. The basic components of a mass spectrometer are:
- A sample inlet that introduces the sample into the instrument
- An ionization source that converts the sample molecules into ions
- An accelerator that imparts kinetic energy to the ions
- A mass analyzer that separates the ions according to their mass-to-charge ratio
- A detector that records the abundance and identity of the ions
- A data system that processes and displays the results
The steps involved in mass spectrometry are:
- Sample inlet: The sample can be in solid, liquid, or gas form. It is introduced into the instrument through a suitable inlet system, such as a syringe, a capillary, a nebulizer, or a gas chromatograph. The sample inlet must ensure that the sample reaches the ionization source in a controlled and reproducible manner.
- Ionization: The sample molecules are ionized by removing or adding one or more electrons. This can be done by various methods, such as electron ionization (EI), chemical ionization (CI), electrospray ionization (ESI), matrix-assisted laser desorption/ionization (MALDI), or atmospheric pressure chemical ionization (APCI). The choice of ionization method depends on the type and properties of the sample and the desired information. The ionization process produces positive or negative ions with different charge states and fragmentation patterns.
- Acceleration: The ions are accelerated by an electric field to give them a uniform kinetic energy. This allows them to travel through the mass analyzer with different velocities depending on their mass-to-charge ratio. The acceleration voltage can be fixed or variable depending on the type of mass analyzer.
- Mass analysis: The ions are separated by a mass analyzer according to their mass-to-charge ratio. There are different types of mass analyzers, such as magnetic sector, quadrupole, time-of-flight (TOF), ion trap, orbitrap, or Fourier transform ion cyclotron resonance (FT-ICR). Each type of mass analyzer has its own advantages and limitations in terms of resolution, accuracy, sensitivity, speed, and range of mass-to-charge ratio.
- Detection: The separated ions are detected by a device that converts their arrival into an electrical signal. The most common type of detector is an electron multiplier, which amplifies the signal by generating secondary electrons from each incoming ion. Other types of detectors include Faraday cups, microchannel plates, or photomultiplier tubes. The detector signal is proportional to the abundance of each ion and is recorded as a function of time or mass-to-charge ratio.
- Data system: The detector signal is processed by a data system that converts it into a mass spectrum. A mass spectrum is a graphical representation of the relative abundance of ions versus their mass-to-charge ratio. The data system can also perform various functions such as peak identification, quantification, calibration, noise reduction, data storage, and display.
The sample inlet process is the first step in mass spectrometry, where the sample is introduced into the mass spectrometer and converted into gas phase ions. The sample inlet process depends on the physical state, volatility, and thermal stability of the sample, as well as the type of ionization technique used. There are different types of sample inlet systems for different applications, such as:
- Direct vapor inlet: This is the simplest and most common type of sample inlet, where a gaseous or volatile sample is directly injected into the ionization chamber through a small orifice. The pressure in the chamber is reduced by a vacuum system to allow ionization and mass analysis. This type of inlet is suitable for samples that are thermally stable and have high vapor pressure .
- Gas chromatography (GC) inlet: This is a type of inlet that combines gas chromatography with mass spectrometry, where a liquid or solid sample is first separated into its components by a GC column and then introduced into the mass spectrometer through a heated transfer line. The GC inlet allows for the analysis of complex mixtures and trace compounds that are otherwise difficult to ionize .
- Liquid chromatography (LC) inlet: This is another type of inlet that combines liquid chromatography with mass spectrometry, where a liquid sample is first separated into its components by an LC column and then introduced into the mass spectrometer through an electrospray or atmospheric pressure chemical ionization (APCI) source. The LC inlet allows for the analysis of polar and non-volatile compounds that are otherwise difficult to vaporize.
- Direct ionization inlet: This is a type of inlet that allows for the direct ionization of solid or liquid samples without prior vaporization or separation. Examples of direct ionization techniques include matrix-assisted laser desorption/ionization (MALDI), desorption electrospray ionization (DESI), and secondary ion mass spectrometry (SIMS). These techniques can ionize large and fragile molecules such as proteins, peptides, carbohydrates, and polymers.
The sample inlet process is an important factor that affects the sensitivity, selectivity, and accuracy of mass spectrometry. The choice of the appropriate sample inlet system depends on the nature of the sample, the analytical objective, and the available resources.
Ionization is the process of converting neutral molecules into charged ions, which can then be separated and detected by mass spectrometry. Different ionization techniques have different advantages and disadvantages depending on the type, state, and complexity of the sample. Some of the most common ionization techniques are:
- Electron Ionization (EI): This technique uses a beam of high-energy electrons to knock out electrons from the sample molecules, creating positive ions. EI is a "hard" ionization technique, meaning it causes extensive fragmentation of the sample molecules, which can provide structural information but also complicate the interpretation of the mass spectrum. EI is suitable for volatile and thermally stable samples that can be vaporized in a vacuum.
- Chemical Ionization (CI): This technique uses a reagent gas (such as methane) that is ionized by electrons and then reacts with the sample molecules to form adduct ions, such as + or -. CI is a "soft" ionization technique, meaning it causes less fragmentation of the sample molecules, which can preserve the molecular ion peak but also reduce the structural information. CI can also be operated in negative mode to generate anions. CI is suitable for samples that are less volatile or thermally stable than EI.
- Electrospray Ionization (ESI): This technique uses a high voltage to create a fine spray of charged droplets from a liquid sample solution. As the droplets evaporate, they release ions of the sample molecules into the gas phase. ESI is a soft ionization technique that can produce multiply charged ions, which can reduce the mass-to-charge ratio and increase the sensitivity of detection. ESI can also be operated in negative mode to generate anions. ESI is suitable for polar and ionic samples that are soluble in a liquid solvent, such as proteins and peptides.
- Matrix-Assisted Laser Desorption/Ionization (MALDI): This technique uses a laser beam to vaporize and ionize a solid sample that is mixed with a matrix compound (such as an organic acid). The matrix absorbs the laser energy and transfers it to the sample molecules, which are then ejected into the gas phase as ions. MALDI is a soft ionization technique that can produce singly charged ions, which can simplify the mass spectrum and increase the mass range of detection. MALDI is suitable for large and complex samples that are not easily vaporized or ionized by other techniques, such as polymers and biomolecules.
These are some of the most widely used ionization techniques in mass spectrometry, but there are many others that have specific applications and advantages. The choice of ionization technique depends on several factors, such as the physical state, chemical properties, molecular weight, and structural complexity of the sample, as well as the desired information and sensitivity of detection.
After the sample molecules are ionized, they are accelerated by an electric field towards the mass analyzer. The acceleration process ensures that all the ions have the same kinetic energy, regardless of their mass or charge. This is important because it allows the mass analyzer to separate the ions based on their mass-to-charge ratio (m/z) without being affected by their initial velocity or direction.
The acceleration process can be achieved by different methods, depending on the type of mass spectrometer. For example, in a magnetic sector mass spectrometer, the ions are accelerated by a series of slits with decreasing voltage. In a time-of-flight mass spectrometer, the ions are accelerated by a short pulse of voltage . In an accelerator mass spectrometer, the ions are accelerated by a high-voltage terminal and then by a linear accelerator.
The acceleration process is crucial for the performance and sensitivity of mass spectrometry, as it determines how fast and how far the ions can travel in the mass analyzer. The higher the acceleration voltage, the higher the kinetic energy and velocity of the ions, and the more they can be deflected by a magnetic or electric field. However, too high of an acceleration voltage can also cause fragmentation or ionization of the ions, which can interfere with the mass analysis. Therefore, the optimal acceleration voltage depends on the type and size of the sample molecules and the design of the mass spectrometer.
The deflection process is the stage where the ions are separated by their mass-to-charge ratio (m/z) using a magnetic field. The principle behind this process is that ions with different m/z will have different trajectories when they are subjected to a magnetic force perpendicular to their direction of motion. The lighter the ion, the more it will be deflected by the magnetic field. The higher the charge of the ion, the more it will be deflected by the magnetic field as well.
The deflection process can be achieved by different types of mass analyzers, such as sector instruments, time-of-flight (TOF) instruments, quadrupole mass filters, ion traps, orbitraps, and Fourier-transform ion cyclotron resonance (FT-ICR) instruments. Each type of mass analyzer has its own advantages and disadvantages in terms of resolution, accuracy, sensitivity, speed, and cost.
Sector instruments use a combination of electric and magnetic fields to deflect and focus the ions onto a detector. They can be single-focusing or double-focusing, depending on whether they use one or two sectors to correct for the initial kinetic energy distribution of the ions. Sector instruments have high resolution and accuracy, but they are relatively slow and expensive.
TOF instruments use an electric field to accelerate the ions to a constant kinetic energy and then measure the time it takes for them to reach a detector at a fixed distance. The time of flight is inversely proportional to the square root of the m/z ratio. TOF instruments have high speed and sensitivity, but they have lower resolution and accuracy than sector instruments.
Quadrupole mass filters use four parallel metal rods with alternating positive and negative voltages to create an oscillating electric field that allows only ions with a certain m/z ratio to pass through at a given time. The m/z ratio can be scanned by varying the voltages on the rods. Quadrupole mass filters have moderate resolution and accuracy, but they have high sensitivity and low cost.
Ion traps use electric or magnetic fields to trap and store ions in a confined space. They can be three-dimensional (3D) or linear, depending on the shape of the trap. Ion traps can perform multiple stages of mass analysis by ejecting selected ions from the trap and detecting them. Ion traps have high sensitivity and versatility, but they have lower resolution and speed than other mass analyzers.
Orbitraps use an electrostatic field to confine ions in an orbital motion around a central electrode. The frequency of the orbital motion is proportional to the m/z ratio of the ion. Orbitraps can measure the frequency of the ions using an image current detection technique. Orbitraps have very high resolution and accuracy, but they have lower sensitivity and speed than TOF instruments.
FT-ICR instruments use a strong magnetic field to induce cyclotron motion of the ions in a circular chamber. The frequency of the cyclotron motion is proportional to the m/z ratio of the ion. FT-ICR instruments can measure the frequency of the ions using a radiofrequency detection technique. FT-ICR instruments have extremely high resolution and accuracy, but they are very expensive and complex.
The detection of ions is the final step in mass spectrometry, where the separated ions are converted into an electrical signal that can be recorded and analyzed. The detector should be able to measure the mass-to-charge ratio and the abundance of the ions accurately and sensitively. There are different types of detectors used for mass spectrometry, depending on the type of mass analyzer and the application. Some of the common detectors are:
- Electron multiplier: This is a device that amplifies the current produced by a single ion hitting a metal surface by generating a cascade of secondary electrons. The electron multiplier is widely used for electron ionization (EI), chemical ionization (CI), and quadrupole mass analyzers .
- Microchannel plate: This is a device that consists of a thin plate with millions of microscopic channels that act as independent electron multipliers. The microchannel plate can detect multiple ions simultaneously and has a fast response time. It is often used for time-of-flight (TOF) and ion trap mass analyzers .
- Faraday cup: This is a device that consists of a metal cup that collects the ions and measures the charge they carry. The Faraday cup is simple and robust, but it has a low sensitivity and cannot detect low-abundance ions. It is mainly used for magnetic sector and inductively coupled plasma (ICP) mass analyzers .
- Photomultiplier tube: This is a device that converts the photons emitted by the ions into an electrical signal by using a series of dynodes that emit secondary electrons. The photomultiplier tube is sensitive and fast, but it requires a scintillator or a phosphor screen to convert the ions into photons. It is mainly used for MALDI-TOF mass analyzers .
- Ion-to-photon detector: This is a device that combines an electron multiplier and a photomultiplier tube to detect both positive and negative ions. The ion-to-photon detector has a high sensitivity and dynamic range, but it is complex and expensive. It is mainly used for Fourier-transform ion cyclotron resonance (FT-ICR) and orbitrap mass analyzers .
The choice of detector depends on several factors, such as the resolution, speed, sensitivity, dynamic range, noise, cost, and compatibility with the mass analyzer and the ionization source. The detector is an essential component of mass spectrometry, as it determines the quality and reliability of the data obtained from the analysis.
Mass spectrometry is a versatile and powerful analytical technique that can be used for a variety of purposes in different fields. Some of the applications of mass spectrometry are:
- Drug testing and discovery: Mass spectrometry can be used to identify and quantify drugs and their metabolites in biological samples, such as blood, urine, saliva, and hair . It can also be used to screen for new drug candidates, study their pharmacokinetics and pharmacodynamics, and monitor their efficacy and safety.
- Food contamination detection: Mass spectrometry can be used to detect and measure contaminants in food products, such as pesticides, antibiotics, hormones, toxins, allergens, and adulterants . It can also be used to determine the origin, authenticity, and quality of food products.
- Isotope ratio determination: Mass spectrometry can be used to measure the relative abundances of different isotopes of an element in a sample. This can provide information about the source, age, history, and environmental conditions of the sample . For example, mass spectrometry can be used for carbon dating, which is a method of estimating the age of organic materials based on the decay of carbon-14 .
- Protein identification: Mass spectrometry can be used to identify and characterize proteins and peptides in biological samples. It can provide information about the molecular weight, amino acid sequence, post-translational modifications, interactions, and functions of proteins . It can also be used to study the structure and dynamics of proteins using techniques such as hydrogen-deuterium exchange.
- Other applications: Mass spectrometry can also be used for other purposes, such as environmental monitoring and analysis , geochemistry , chemical and petrochemical industry, forensic science, clinical diagnostics, biotechnology, and astrochemistry.
Mass spectrometry is a rapidly evolving field that continues to offer new possibilities and challenges for analytical chemistry. As new ionization techniques, mass analyzers, detectors, and data analysis methods are developed, mass spectrometry will become more sensitive, selective, accurate, and comprehensive. Mass spectrometry will also benefit from the integration with other analytical techniques, such as chromatography, spectroscopy, microscopy, and bioinformatics. Mass spectrometry will remain an indispensable tool for exploring the molecular world.